Accuracy of three imaging modalities for evaluation of the posterior lens capsule in traumatic cataract

Category: Articles » Others

Accuracy of 3 imaging modalities for evaluation of the posterior lens capsule in traumatic cataract

 

Click below link:

 

Accuracy of three imaging modalities for evaluation of the posterior lens capsule in traumatic cataract

 

 

 

Accuracy of 3 imaging modalities for evaluation of the posterior lens capsule in traumatic cataract.

Abstract

PURPOSE:

To compare the accuracy of 3 imaging modalities for preoperative evaluation of the posterior lens capsule in traumatic cataract.

SETTING:

Farabi Eye Hospital, Tehran, Iran.

DESIGN:

Case series.

METHODS:

The study comprised eyes with traumatic cataract opaque enough to prevent visualization of the posterior lens capsule on slitlamp examination. To detect posterior lens capsule rupture before surgery, imaging was performed with 20 MHz echography (Eye Cubed), anterior segment optical coherence tomography (AS-OCT) (Visante model 1000), and Scheimpflug imaging (Pentacam). All patients subsequently had cataract extraction, and the intraoperative findings of the posterior lens capsule were compared with the preoperative findings of the imaging modalities.

RESULTS:

The study enrolled 21 eyes of 21 patients (20 men, 1 woman) with a mean age of 31.5 years ± 1.45 (SD). The nature of trauma was blunt (5 eyes) or sharp (16 eyes). To detect posterior lens capsule rupture, the sensitivity and specificity were, respectively, 80% and 86% for 20 MHz echography, 71% and 77% for AS-OCT, and 62% and 57% for Scheimpflug imaging (95% confidence intervals: sensitivity, 30.00-90.32; specificity, 54.81-92.95). Insufficient resolution for posterior lens capsule evaluation occurred in 33.3% cases for AS-OCT and 57.1% cases for Scheimpflug imaging. The accuracy of 20 MHz echography, AS-OCT, and Scheimpflug imaging was 76.1%, 61.9%, and 42.9%, respectively.

CONCLUSION:

In the evaluation of the posterior lens capsule in eyes with traumatic cataract, 20 MHz echography had higher accuracy than AS-OCT and Scheimpflug imaging.

About Us :

Dr. Alireza Arefzadeh
Assistant Prof of Endocrinology & Metabolism
Faculty Member of Medical University
Internal Medicine Specialist
Endocrinology and Metabolism SubSpecialist
Clinician and Researcher
Member of American Diabetes Association(ADA).
Member of European Society of Endocrinology(ESE)and European Research Association(CORDIS).

Contact Us :

Address :Norrebrogade, Copenhagen N, 2200 Denmark.
Phone :004591731837
E-mail :info@drarefzadeh.com
Contact TEL Number for patients outside Iran: 0016612623255-0037253141799-00447700309990
Contact TEL Number for patients inside Iran: 02122898836-09198673034-09373622621
آدرس: تهران، خیابان شریعتی، بالاتر از میرداماد، روبروی مترو شریعتی، جنب پمپ بنزین شریعتی(مینا)، کوچه شواری، پلاک 29، ساختمان پزشکان سینا، طبقه4، واحد 16. روزهای زوج از ساعت 5بعداز ظهر تا 7 شب تلفن تماس:09198673034-02122898836 تلفن پاسخ گویی به سوالات09373622621
 

سئو فروشگاه اینترنتی | کاشت مو غرب تهران | صندلی ناصر پلاستیک | مزوتراپی مو